# [sketch] MVP ventilation

### Rear - Outflow

<s>50 CFM outflow from rear via dedicated $100 blower.</s>

It turns out a more standard blower is probably not ideal for the high static pressure of a 3" pipe run.

A radon fan may be more suitable, at a slight increase in purchase cost and running cost.

Main radon fan manufacturers appear to be RadonAway &amp; Fantech, some options:

Leaning towards [Festa AMG Triumph ECS](https://www.festaradontech.com/products/amg-triumph-ecs?variant=48254637932801)

### Table of fan comparisons

[![RC-basement-fan-01a.jpeg](https://wiki.ridgewoodcommons.nyc/uploads/images/gallery/2026-11/scaled-1680-/rc-basement-fan-01a.jpeg)](https://wiki.ridgewoodcommons.nyc/uploads/images/gallery/2026-11/rc-basement-fan-01a.jpeg)

[![RC-basement-fan-02a.jpeg](https://wiki.ridgewoodcommons.nyc/uploads/images/gallery/2026-11/scaled-1680-/rc-basement-fan-02a.jpeg)](https://wiki.ridgewoodcommons.nyc/uploads/images/gallery/2026-11/rc-basement-fan-02a.jpeg)

[![RC-basement-fan-03a.jpeg](https://wiki.ridgewoodcommons.nyc/uploads/images/gallery/2026-11/scaled-1680-/rc-basement-fan-03a.jpeg)](https://wiki.ridgewoodcommons.nyc/uploads/images/gallery/2026-11/rc-basement-fan-03a.jpeg)

[![RC-basement-fan-04a.jpeg](https://wiki.ridgewoodcommons.nyc/uploads/images/gallery/2026-11/scaled-1680-/rc-basement-fan-04a.jpeg)](https://wiki.ridgewoodcommons.nyc/uploads/images/gallery/2026-11/rc-basement-fan-04a.jpeg)

### Exhaust fan options: 3" iron pipe, ~20 ft vertical, 2–3 × 45°, open top

Annual cost = max rated watts × 8,760 h × $0.29/kWh (Con Ed residential, 2026). Commercial accounts run ~15–25% lower. "Est. on pipe" = estimated operating point on this run. "—" = not published / not found.

**Rn4EC-3 rated points (3" duct):** 100%: 36 CFM @ 4.5" (146 W), 210 CFM @ 0.2" (173 W). 80%: 29 CFM @ 3.19" (88 W), 180 CFM @ 0.2" (126 W). 60%: 20 CFM @ 1.75" (40 W), 130 CFM @ 0.2" (57 W).

**Notes for coffee roasting exhaust (1 kg electric, tented):**  
\- Measure air temp at the fan inlet during the darkest roast. Above ~104°F, only the 1TDV2 is rated for it.  
\- Oil residue condenses as smoke cools. Scroll blowers can be opened and cleaned; radon fans are sealed and effectively consumable in this use.  
\- Use a washable mesh/baffle grease filter at the tent outlet.  
\- Fan at the top (pulling) keeps the iron pipe under suction, so leaks in the ceiling space draw air in rather than leaking smoke out.  
\- Add a cleanout/drip cup at the bottom of the vertical run.  
\- Est. on-pipe figures are rough calculations, not measurements.

Reduces roasting impact, improves CO2 and VOC reduction.

### Front - Inflow/Outflow switchable

Big dust collection blower near hatch.  
With longer hoses on in/out, could swap between inflow/outfow.  
Hose can hook on to 1/2 opened hatch door.  
Would be better with ducting, but routing past electrical panel and lift would be difficult.

##### Inflow

Set up for inflow, would work in tandem with rear exhaust.

##### Outflow

Set up for exhaust, could make the front area suitable for painting/staining.  
Would benefit from cordoning off area to avoid drafts to upstairs or rest of basement.  
Probably doesn't need to be entirely enclosed to help.

### Next Steps

To improve outflow from rear, add additional exhaust:

- ...via 4-6" round conduit, routed through gym square duct and window
- ...vita large diameter duct through 1st floor mainspace bathroom, to roof. (Could have inline register in bathroom)

To improve incoming airflow from front, add additional incoming ducting:

- ...from right front facade window upper sash panel, routed to basement via duct tucked into the corner