Rear - Outflow

50 CFM outflow from rear via dedicated $100 blower.

It turns out a more standard blower is probably not ideal for the high static pressure of a 3" pipe run.

A radon fan may be more suitable, at a slight increase in purchase cost and running cost.

Main radon fan manufacturers appear to be RadonAway & Fantech, some options:

Table of fan comparisons

Exhaust fan options: 3" iron pipe, ~20 ft vertical, 2–3 × 45°, open top

Annual cost = max rated watts × 8,760 h × $0.29/kWh (Con Ed residential, 2026). Commercial accounts run ~15–25% lower. "Est. on pipe" = estimated operating point on this run. "—" = not published / not found.

Model

Type

Price seen

Max W

Annual cost, full tilt

CFM @ 0"

CFM @ 0.5"

CFM @ 1.0"

CFM @ 1.5"

CFM @ 2.0"

Max SP

Est. on pipe

Max air temp

Speed control

Ports

Motor / service

Dayton 42NL22

(current)

FC scroll blower

$97.23 Grainger

$79.99 Zoro

~52

~$132

75

62

0

—

—

1.0"

~55 CFM

104°F

No

2-1/8" round flange

Outboard motor; housing opens

Dayton 1TDP5

FC scroll blower

$79.99 Zoro

~75

~$190

131

105

—

—

—

—

~75 CFM

104°F

No

Square flange

Outboard motor; housing opens

Dayton 1TDV2

FC scroll blower, high-temp

$175.81 PartsSource

$119.95 interchange

~75

~$190

129

91

—

—

—

—

~80–90 CFM

450°F inlet

(motor ambient 104°F)

No

Rectangular

Outboard motor; housing opens

RadonAway RP145

Inline radon fan

—

72

~$183

166

126

82

41

3

2.1"

~90 CFM

check spec

No

4"

Motor in airstream; sealed

RadonAway GP501

Inline radon fan, high pressure

$270 HVACQuick

146

~$371

—

—

95

—

—

4.2"

~105–110 CFM

check spec

No

3"

Motor in airstream; sealed

Fantech Rn2

Inline radon fan

$185.90 HVACQuick

58

~$147

160

120

80

40

—

1.97"

~85–90 CFM

check spec

No

4.5" (needs reducer)

Motor in airstream; welded housing

Fantech Rn3

Inline radon fan

—

141

~$359

370

280

180

120

50

2.36"

~110–115 CFM

check spec

No

6" (needs reducer)

Motor in airstream; welded housing

Fantech Rn4EC-3

Inline radon fan, EC variable speed

$365.90 Home Depot

$392.99 HomElectrical

$447 HVACDirect

173

~$439

(~$145 at 60%)

210 @ 0.2"

—

—

—

—

4.5"

~85 CFM @ 60%

~110 @ 80%

~130 @ 100%

check spec

Yes: dial or 0–10 V input

~6"; 6×3" couplings included

Motor in airstream; welded housing

Rn4EC-3 rated points (3" duct): 100%: 36 CFM @ 4.5" (146 W), 210 CFM @ 0.2" (173 W). 80%: 29 CFM @ 3.19" (88 W), 180 CFM @ 0.2" (126 W). 60%: 20 CFM @ 1.75" (40 W), 130 CFM @ 0.2" (57 W).

Notes for coffee roasting exhaust (1 kg electric, tented):
- Measure air temp at the fan inlet during the darkest roast. Above ~104°F, only the 1TDV2 is rated for it.
- Oil residue condenses as smoke cools. Scroll blowers can be opened and cleaned; radon fans are sealed and effectively consumable in this use.
- Use a washable mesh/baffle grease filter at the tent outlet.
- Fan at the top (pulling) keeps the iron pipe under suction, so leaks in the ceiling space draw air in rather than leaking smoke out.
- Add a cleanout/drip cup at the bottom of the vertical run.
- Est. on-pipe figures are rough calculations, not measurements.


Reduces roasting impact, improves CO2 and VOC reduction.

Front - Inflow/Outflow switchable

Big dust collection blower near hatch.
With longer hoses on in/out, could swap between inflow/outfow.
Hose can hook on to 1/2 opened hatch door.
Would be better with ducting, but routing past electrical panel and lift would be difficult.

Inflow

Set up for inflow, would work in tandem with rear exhaust.

Outflow

Set up for exhaust, could make the front area suitable for painting/staining.
Would benefit from cordoning off area to avoid drafts to upstairs or rest of basement.
Probably doesn't need to be entirely enclosed to help.

Next Steps

To improve outflow from rear, add additional exhaust:

  • ...via 4-6" round conduit, routed through gym square duct and window
  • ...vita large diameter duct through 1st floor mainspace bathroom, to roof. (Could have inline register in bathroom)

To improve incoming airflow from front, add additional incoming ducting:

  • ...from right front facade window upper sash panel, routed to basement via duct tucked into the corner